marquis spas Due to the warm water temperature and high evaporation rate, the total dissolved solids tend to build up. Thread plugs into the threaded cartridge mounts in the filter box. WARNING! 2) Add a Brightener 24 hours after adding the Scale Preventative. Make sure to vacuum until you feel no more water coming out, then block the 2 cartridge mounts or block the Elite or Teleweir opening. 3) Provide sufficient work area around the spas perimeter especially the side the spas equipment is located on. b) Such that the weight of the spa, water and bathers is not supported by the spa lip. 4) All field installed metal components such as rails, ladders, drains or other similar hardware within 3m (10 ft.) of the spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than No. b) At least two lugs marked \"BONDING LUGS\" are provided on the external surface or on the inside of the supply terminal box or compartment. LOCATING A CONDUIT WITHIN A CONCRETE PAD If your intent is to bring a conduit and power wires up under the spa we suggest that it enter the spa cavity in the front, left corner; 6 (15cm) Dimension A in from the left and 6 (15cm) Dimension B up from the front. 5) On an ultraviolet ozonator, check the glow fitting on the ozonator for a blue colour to ensure that the bulb is on. 1) When the spa is full, add a scale preventative to inhibit staining and scale formation. c) On a concrete pad where you have a conduit or cable coming up within the perimeter of the spa, you can easily cut an opening in the polyethylene bottom to access the cable or conduit/wires. This fact is noted on the outer spa packaging.Celebrity Spas 2018 Owners Manual DOC: OM-CELEBRITY-18 41 Do not permit any electrical appliance, such as a light, telephone, radio, or television,within 5 feet (1.5m) of a spa.WARNING: To reduce the risk of injury: a) The water in a spa should never exceed 40C (104F). This must be done by employing a qualified electrician and in accordance with local electricalcodes.Note: This 240V conversion allows the heater to operate as a 4Kw at 240V. 4) Use an ohmmeter to check the fuse. Do Not operate the spa with low water levels. 1) Install the spa both physically and electrically, in accordance with any local codes. NORTH AMERICAN (60HZ) MODELSPlease note the following important information:When using this electrical equipment, basic safety instructions should be followed, including the following:Read and Follow ALL Directions 1) Electrical installation must be carried out by a qualified electrician strictly in accordance with local governing codes. INSTALLATION INSTRUCTIONSRemember, your new spa is a powerful piece of electrical and plumbing equipment. 7) Whenever adjusting spa chemicals, less is better. READ AND FOLLOW ALL INSTRUCTIONSWhen using this equipment, basic safety precautions should always be followed. Water temperatures between 38C (100F) and 40C are considered safe for a healthy adult. 3) With the bromine sanitizing system, contaminants may build up during the week. To reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment. Jet(s) Do Not Come On When Pump Key is PressedProbable Jet pump is not plugged into spa pack.cause #1:Action: Plug pump in and test.Probable Jet pump fuse blown in spa pack.cause #2: Locate & test/replace pump fuse in spa pack. Keep cover on and level at all times when spa is not in use. FILLING YOUR SPAOkay, your new spa has been connected to the power and you have a basic understanding of how the equipmentworks and what the jets can do for you. Maximum initial water level should be 6 below the spa lip. 4) Rinse the cartridge thoroughly to remove all the cleaner. On models without a circulation pump, the low speed of the pump is used to circulate the water so it can be filtered and heated. 3) Attach the appropriate size hose to the drain connection (see below). ( 4 hours per a 12 hour period) 2) Test pH to maintain a level of 7.2 to 7.6. This will help draw water out of any lines connected to the spa pack, especially for spas that do not have a circ pump.40 DOC: OM-CELEBRITY-18 Celebrity Spas 2018 Owners Manual 2) Use pliers to remove the fuse from its fuse holder. Each fuse has a voltage and amp rating listed on it and should be used to obtain a replacement fuse.Note: A single fuse may protect more than 1 component in your spa.WARRANTY SERVICEIn the event that you require warranty service, please call the authorized dealer where you purchased the spa. 3) Check your pH, total alkalinity and calcium hardness as recommended by your Sunrise Spa dealer, and adjust if required. See the spa ratings label for current, wire size and breaker requirements. This will ensure that the bubble mist entering your spa is coming through the Sunrise Fresh Water Ozone system.REMEMBER: Your spa water cannot be treated if the circulation system is not operating. Contact dealer if problem persists.Action:Probable Jet pump is not primed.cause #3: Shut off spa and allow trapped air to escape. Take measures to ensure others do not use spa.Spa is Completely Dead (No Circulation and No Display on Topside ControlPanelProbable GFCI/RCD has tripped (shut off).cause #1:Action: Reset GFCI/RCD and monitor for futures trips. 2) Remove the decorative top cover. 3) Replace fuse and test system.These types of fuses are available from your local dealer and may be available from local electronic stores and homecentres. Install at least 5 feet (1.5m) from all metal surfaces. The volume adjustment of the jet internals in these jets can beeffected by debris in the spa water. Adjust it as needed to achieve the best effect from the water feature.WaveWATER FEATURES LED Pop Up Water Feature (Aqua Mini Stream) / Water Ropes Located along the deck of the spa, these water features create a water rope effect into the spa when turned on.MISCELLANEOUS LED Spa Light This clear or slightly bluish fitting is usually in the vertical surface of the spa steps. Spas running on 120VAC will have a longer initial heat-up time.Always view the temperature display before entering the water. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times.DANGER: Risk of Injury. 34 DOC: OM-CELEBRITY-18 Celebrity Spas 2018 Owners Manual Celebrity Spas 2018 Owners Manual DOC: OM-CELEBRITY-18 31 Never lift or carry the spa by its'plumbing.SITE CONSIDERATIONS Local building, property and electrical codes may affect your installation. Do not stand on the hard cover. Never use abrasive cleaners. This owner's manual will helpyou understand your spa, so you will get the most from your investment. The spa should be shocked with a Spa Shock. LED Light(s) Do Not Come On When Light Key is PressedProbable Light fuse blown in spa packcause #1:Action: Locate and test/replace light fuse in spa pack Call dealer if problem persists.Probable In -line or on board fuse blown in LED controllercause #2: Locate and test/replace light fuse in LED control box.Action:No Air/Water Mixture Coming From a JetProbable Air control is closedcause #1:Action: Open air controlProbable Water volume through jet is too low to draw aircause #2: Increase water volume by turning jet faceAction:Probable Adjustable jet internal is loose.cause #3: Tighten jet internalAction:Probable Jet internal is broken or damagedcause #4: Replace jet internal with another one from the spa or with a new one.Action:Probable Debris inside the jet internalcause #5: Remove the internal, inspect for debris, remove debris and re-install. A reading of infinity means the fuse is open and must be replaced.Cartridge Fuses & Small Cartridge Fuses 1) Shut off power to the spa. The cleaning solution should beapplied and immediately wiped dry. Large amountsof chemical can become concentrated in one area and damage the acrylic surface. 3) Check the inside of the jet body and the internal for any debris and calcium build up. Always turn off the spabefore removing the cartridge(s) Debris can enter plumbing and cause damage.50 DOC: OM-CELEBRITY-18 Celebrity Spas 2018 Owners Manual. Do not drag the cover across the spa or decking. View when using a lounger & ease of access for servicing.Spa step out locationSpa Direction These may flood the spa area, damage spa or create a safety hazard to bathers.Downspouts and naturaldrainage of land You will need a place to safely drain the spa and a way to refill it easily.Outside water supply anddraining locationOptional accessories These may take up added space that you must plan for (cover remover/holder).SPA SUPPORTWhatever the support is, it must be: a) A continuous, level surface, above grade, capable of handling 80 lbs. A level 4\" over the bottom of the skimmer mouth is recommended. c) Before entering a spa, the user should measure the water temperature since the tolerance of water temperature-regulating devices varies. This special fuse is designed to open (burn out) if: a) There is any problem with how the electrical supply is connected b) There is a power surge to the spa pack This fuse is not replaceable and the entire spa pack is considered destroyed. Such an occurrence, however, is very unlikely, since each output of the spa pack isindividually fused and fuses will blow before the GFCI trips. You may also wish to attach any notes you have made about the dealer delivery, dealerstart up demo or any other notes that may be of benefit in the future.6 DOC: OM-CELEBRITY-18 Celebrity Spas 2018 Owners Manual
On some models, all equipment is accessible from the main access panel.The free standing spa pack houses the receptacles and switching apparatus (circuit board) for the pump(s) blower,light, keypad etc., as well as the heat regulating system. Check if circ pump is plugged in or if circ pump fuse in spa pack is burnt out.Probable Spa is not covered when not being used.cause #3: Cover spa to retain heat.Action:Probable Heater is not on due to error message showing on display.cause #4: Check for open gate valves on equipment, correct low water level in spa, and examineAction: condition of filter cartridge(s). It's hard, non-poroussurface prevents dirt from accumulating and resists stains better than other plastic materials. )Heater size (kw)Filter Cartridge (Model Number/Size)Topside Control/KeypadSpa Pack Model #Spa Pack Serial #Dealer NameDate of PurchaseWe strongly recommend that you attach your bill of sale to this manual after installation is complete. For Elite or Teleweir filtersystem, remove the Vane weir/trim ring and float assembly. YouLocal codes may need to access from a neighbour's yard or employ a crane. If this is the case, please take time to inspect your spa and reportany damage or missing items to your dealer. The spa pack is also where the electrical supply connectionsare made. 2) The jet face will feel as if it has stopped but if you continue to turn the face, the jet internal will thread out of the body. Contact your dealer and/or a qualified electrician immediately. GFCI trips on newly installedspas are predominantly caused by mis-wired GFCIs.SPECIAL NOTE: DISCONNECT SWITCHThis unit must be connected to a disconnect that de-energizes power to the entire unit for servicing, maintenance orthe like. 9) Don't forget to close the drain before refilling. TEST the GFCI upon every use of the spa.If the GFCI does not shut the spa off when the TEST button is pressed or does not start up when the RESET button ispressed DO NOT USE THE SPA. 11) Provide a copy of your bill of sale, if requested by the dealer or Leisure Manufacturing Inc.Celebrity Spas 2018 Owners Manual DOC: OM-CELEBRITY-18 5 They can loosen during transportation. 32 DOC: OM-CELEBRITY-18 Celebrity Spas 2018 Owners Manual If problemAction: persists bleed air at pump directly by opening union on pump until all entrapped air is released. RifledCelebrity Spas 2018 Owners Manual DOC: OM-CELEBRITY-18 17 4) Route the hose to an appropriate drain location. Turn spa power off then back on. It serves as a safety feature; lighting the spa's contours for those entering or exiting the spa.Celebrity Spas 2018 Owners Manual DOC: OM-CELEBRITY-18 19 For this reason we recommend draining and refilling the spa every 2 to 4 months - depending on usage. As long as the difference is less than 0.5 ppm, the powerful oxidizer from the Fresh Water Ozone system is entering your spa and cleaning your water. Always replace fuses with the same style and amp value as shownon the label inside the wiring compartment!Small Glass Fuses 1) Shut off power to the spa. Celebrity Spas 2018 Owners Manual DOC: OM-CELEBRITY-18 35 Note: Any RV style or plumbing system anti-freeze used may leave behind a residue that could cause a white \"fizz\" inthe first refill of water, especially when the jet pump(s) are turned on. Any custom built enclosure, either above or below a deck surface, must be able to be removed with relative ease. 4) Check the bubble mist entering the spa, via the dedicated ozone/return jet, for consistency. Use a moving dolly and/or straps to more evenly distribute the spa's weight. See above table for recommended opening location.You may wish to insulate any opening or cut-out you make in the spas cabinet panel or corner or bottom to keep coldair and small animals out.Celebrity Spas 2018 Owners Manual DOC: OM-CELEBRITY-18 11