I invested in a good rubber mallet to knock the band into seat as I tightened it down. 0000138322 00000 n
endstream Is the pump too strong or what's the deal? My backwash valve has a crack in the side so I need to replace the entire assembly. Place the o-rings on the face of the union tail. The two most common model #'s for this valve are the, If you are still having trouble determining the fix for your Hayward backwash valve then please comment below with the information indicated in step #2 and we will let you know the appropriate fix. Does anyone actually LIKE their pool decking??? Jun 10, 2015. Next remove the backwash handle,compression ring and tank. We can try to narrow down the choices if you can identify the model number of your filter. endobj Could be a burr or such on the inside tube or ? Sprayed wd40 on the band to help it slide around the housing and clamp tighter. I adhesived the gasket in place and replaced the valve top. After removing the bolts, lift up the handle, bringing the lid and key stem with it. Thanks in advance for your help. 60514-01 $9.00 Add To Cart Brine Cam Gear Minutes 60514-02 $8.95 Add To Cart Brine Fitting BLFC Brass part 13244 $13.95 Add To Cart We are a registered 501(c)3 non-profit that is funded by user donations. If the stem through the center is leaking there are some parts to change on the valve stem. 576 0 obj Please consider. 576 69
Pentair plc (NYSE:PNR), a leader in helping the world sustainably move, imp. . Is your valve handle loose or jiggly? Suction leak allowing air into the water flow. Verify filter and skimmers are clean, backwash . 0000137721 00000 n
filter with a new one. Any idea on part I need maybe number? 5. One of the most popular filter manufactures in the world is Hayward Pool Products who also makes quite a few backwash valves. If you have one of the following Hayward valves which is leaking then the appropriate fix would be to replace the spider gasket within the valve. Always wipe down the gasket with a clean cloth and ensure the seat around the filter is also very clean Hello , This is an inactive thread. 0000090579 00000 n
What valve should I buy that will work on this sand filter model? When water is leaking out the backwash port its usually the spider gasket also, you can get by temporarily by putting a 1.5 winterizing plug with o-ring and that will stop the leak but this is just until you can replace the gasket. I have a Pentair (Pac Fab) series 2000 DE filter with built in backwash valve that is leaking out the backwash port at a rate of 6 or 7 drops per minute. I assume that it is the seal on the valve. Report. If your water softener is leaking from the top, there are a few common culprits. <>stream
Leaky Pentair backwash valve | Kool Pool Care (602) 677-4568 - YouTube http://koolpoolcare.com3245 W Florimond Rd, Phoenix, AZ 85086(602) 677-4568When I went to one of my weekly pool service. 0000087069 00000 n
0000022179 00000 n
Did you check the handle to determine if it is loose/jigglingwhich can be a sign of a baddiverterspring. When it is placed in recirculate mode, water comes out the waste opening. 0000131517 00000 n
This short video demonstratio Don't miss. I disassembled completely and cleaned everything but still leaks. Thanks in advance for your help. Posted: 9/4/2020, InyoPools Product Specialist Matt S.
The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Any new postings here are unlikely to be seen or responded to by other members. You are using an out of date browser. LEAK TRAC 2400 W/WIRELESS TECH ANDERSON. Multiport Valve Leaks Around The Cover When the cover on your multiport valve leaks, the first thing you should check is your system's pressure. If your valve handle is loose or jiggly, you may have a bad diverter spring, which helps make the pinwheel diverter seal against the spider gasket. Cloudflare is currently unable to resolve your requested domain. Same here. The diverter valve is on the pipe coming from the pump basket and diverts the flow either to the filter or to a waste line. For a better experience, please enable JavaScript in your browser before proceeding. hbbb`b``3
1` M D 0000002112 00000 n
0000097986 00000 n
If the handle is stiff, then I would open the valve to find out if the spider gasket or something else is the cause.With either of those options, you should consult the. However, if I move the handle just a quarter of an inch countercloskwise ( toward the backwash position) the leaking stops. Posted: 8/25/2020, Kim
However, I would need a deposit of 75%. 0000010986 00000 n
For a better experience, please enable JavaScript in your browser before proceeding. Thats still an easy (temp) build for a sunscreen. 5 out of the five times I have backwashed my filter, the push/pull valve has developed a small leak at the top around base of the handle. 4. It is being practiced by thousands of pool owners just like you. Pressure side leak but pipes held pressure? Pentair 51013811 Complete Valve Stem with Handle Replacement Push Pull Pool and Spa Valve. How To Fix If your pump's lid leaks, you'll need to replace either the lid or the O-ring, depending on the source of the leak. For a better experience, please enable JavaScript in your browser before proceeding. sand filter or D.E filter). Posted: 5/25/2022, Jess
0000005215 00000 n
Water chemistry out of wack? You go kriss cross with the clamp tightening. It is being practiced by thousands of pool owners just like you. I replaced the diverter because the spider gasket was the type built in. No its not loose. Email us at upload@inyopools.com, Copyright 2023 INYOpools All rights reserved, How to repair a leaking Hayward backwash valve. https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=4&cad=rja&uact=8&ved=0ahUKEwiwk9-54OLSAhXDNSYKHR8mDBQQFgi5ATAD&url=http%3A%2F%2Fwww.pentairpool.com%2Fpdfs%2F270163.C-TwoPositionSlideValve.pdf&usg=AFQjCNHF4czLwtNOg-J86In80y83JSTUyw&sig2=-oHPgpRNx3Z8LDw-UcQvFg&bvm=bv.149760088,d.eWE, https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=2&cad=rja&uact=8&ved=0ahUKEwjI8oOQ4-LSAhWGNiYKHVmOBx0QFgglMAE&url=https%3A%2F%2Fwww.physics.harvard.edu%2Fuploads%2Ffiles%2Fmachineshop%2Fepm_oring_handbook.pdf&usg=AFQjCNGhn7SJlwDBQC6FOik17KuUwNxMtA&sig2=WsT1o4kYPJ9NY8BSvZICkg. 0000011913 00000 n
0000008512 00000 n
The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. 0000006869 00000 n
Remove the o-rings (2 total) from the packaging. A dirty filter or a closed return valve can cause high pressure and lead to leaks. Dirty or worn filters or clogged lint traps. If they believe it is warped and are willing to replace it as a defective, have them replace it. JavaScript is disabled. Recommendations for Stain & Seal concrete patio around saltwater pool. Confirm correct valve is being used; DE valves for DE filters and Sand valves for Sand filters. Hope it makes sense. Would be nice to have something. %%EOF 0000147593 00000 n
0000009141 00000 n
How do you get the backwash handle off the rotary shaft? The backwash valve is the valve which is mounted on either the top or side of your filter tank and are specifically used clean sand filters or DE filters. 0000011436 00000 n
Pricing comparison between finishes to resurface small inground? Remember to tighten the clamps in a kriss cross manner. How to Replace a Spider Gasket or Multiport Gasket on a Pool filter multiport valve. POOL BACKWASH VALVE LEAKING (HOW TO FIX) Lex Vance 57.8K subscribers 50K views 5 years ago If you'd like to support the channel, you can do so by shopping for whatever you need on AMAZON. 0000059645 00000 n
The idea is to release the compression slowly and evenly. If you are having trouble finding the valve # on the label then you may be able to find a SP or SPX part # molded into the plastic of the body of the valve or the handle. 0:00 / 4:41 Leaking Out Of The Backwash KrossberPools 875 subscribers Subscribe 225K views 9 years ago This is another instructional video from Krossber Brothers Pool and Spa. Recommended fix for this, please! Carton Wt. 0000005798 00000 n
We replaced the spider gasket and the backwash is still leaking. 0000022414 00000 n
You must log in or register to reply here. Hi
http://www.pentairpool.com/pool-ownection.php?s=51, Pool Water: Treatment, Testing & Problems (P), Testing and Adjusting Pool Water Chemistry, Using Chlorine and Chlorinating Chemicals, Salt Generators (SWCG) & other Chlorine Feeders. How do you lubricate or replace it. This valve is the source of water for the softener. Leaking Air Relief 644 0 obj The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. I have a crack on valve model # spo714g11 and need to replace it
4. . endobj Is this something I can do myself, I'm pretty handy. %PDF-1.4
%
It's rare to have a valve be bad out of the box, but if it is, there is no need to fiddle around. 0000010511 00000 n
Pentair to Release First Quarter 2023 Earnings and Host Investor Conference Call on April 27. The only thread I saw where there was an issue with a 2/3 way diverter valve, it appeared that the water was leaking out of the valve itself and not the waste line. Some common parts to check are the lid o-ring, drain plug o-ring, and pump union o-rings. What are your test readings? Hello , This is an inactive thread. The filter is only about 7 yrs old. Then remove the handle extension from the rotor shaft. but it fixed the leak. Posted: 6/24/2020, InyoPools Product Specialist Matt S.
and the valve # will be located in this box. Posted: 9/2/2020, InyoPools Product Specialist Matt S.
This year after opening the pool, I noticed that when the diverter is in the off position for the waste line (that is, the water is flowing to the filter) water continues to drip from the waste line. 0000003452 00000 n
Please consider. In the video I show the unique nature of this broken Pentair backwash valve and it's successful pool repair.Social Pageshttps://www.facebook.com/koolpoolcare/https://plus.google.com/+KoolPoolCareandRepairPhoenix/abouthttp://www.yelp.com/biz/kool-pool-care-and-repair-phoenixKool Pool Care Video Channel 25K views 11 years ago http://www.poolguysupply.com Learn how to replace your old rotor (backwash) valve for your pool and spa D.E. Plumb pump piping to center pipe in valve. As your end-to-end custom water treatment solutions provider, you can count on our team of Pentair water experts, and network of service providers, to help solve your water-using equipment needs. I had my sand filter replaced with a cartridge filter several seasons ago. Figured the spider gasket was worn so bought an entire new Hayward SP0714T VariFlo Top-Mount Multiport Valve as price was decent. Posted: 5/12/2022, InyoPools Product Specialist Matt S.
A suction leak in the pump can push some DE into the pool via the skimmer or main drain when the pump is turned off. One of the most common problems pool owners run across when maintaining and serving their swimming pool is a leaking backwash valve. JavaScript is disabled. Any new postings here are unlikely to be seen or responded to by other members. I used a wood block and hammer to gently tap down to press the seal every few turns. Learn how to do a full backwash and cleaning on a Pentair FNS D.E. 3. Do you have this model? Posted: 7/18/2021, InyoPools Product Specialist Matt S.
Thanks. Posted: 4/7/2021, Steven G
If you need to clean the filter the casing comes right apart. http://www.poolpartsonline.com/p-174-pentair-compool-diverter-and-check-valve-parts-15-and-2.aspx, Replacing sand filter with a cartridge filter, Need help replacing suction valve for pool spa, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Mine is doing the exact same thing! Thank god. Posted: 5/4/2021, Tim
Came back out and the leaks stopped. I wont go into the details of my return-side plumbing but, suffice it to say, there are two diverter valves (Pentair 2 3-way valves) there. A variety of valves have been designed for backwash functions, but the repair task is made somewhat easier by the fact that there are only three basic types of backwash valves: rotor, push-pull and multiport. It is being practiced by thousands of pool owners just like you. First, turn off the swimming pool's filter pump. Hi. Any new postings here are unlikely to be seen or responded to by other members. ?? Posted: 5/28/2021, InyoPools Product Specialist Matt S.
The valve shows SP0710G11 Rev.C 24. If this is your first visit, be sure to
Filter. For a better experience, please enable JavaScript in your browser before proceeding. 0000007070 00000 n
The majority of Hayward valve part #s start with this prefix SP7. Excessive pressure? Just wanted to add a closing comment: to this: after a few days of letting the pump filter as normal while i debated on what to do, the leak stopped on its own. Winterizing 1. Using a pool lubewill prevent it from dry rotting, and can help in sealing up a leaking drain plug. Helpful information for us would be any part #s off of the valve, the filter manufacture name, the filter model name, filter model #, filter square footage, number of positions the valve can be set to, plumbing size going into the valve and filter type (i.e. 2. The hard part is getting the rotor out of the body, they make a special puller but after you remove the handle extension from the rotor shaft you can put a 2x4 under the shaft and stand on the body giving upward pressure on the rotor, if you spin the rotor at this time it will come up. A91438D3-4F5D-4FD4-931C-B4635B774379.jpeg, 309FB8E5-AB39-40C6-B462-49FA56C5A9BF.jpeg, Texas, San Antonio/Marion, South-Central Area, D5A2EC2E-7A58-47E8-9ED9-4CD21DE714DE.jpeg, Correct placement Pentair high flow diverter, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Posted: 9/3/2020, InyoPools Product Specialist Matt S.
d. Remove the existing valve from the lter. This is because there are diverter stem o-rings that should be water from exiting the top cover. My model number shows SP0714G11M and I can't find it. 0000137974 00000 n
0000009631 00000 n
This valve also contains a seal. http://koolpoolcare.com3245 W Florimond Rd, Phoenix, AZ 85086(602) 677-4568When I went to one of my weekly pool service customer's house today I noticed the backwash hose was filled with water and ready to explode. You are using an out of date browser. I called today to have it replaced under warranty a second time! 3. Sounds like you did try everything and did it all right. 0000031874 00000 n
0000124239 00000 n
0000006216 00000 n
Presume it is the top oring. We are a registered 501(c)3 non-profit that is funded by user donations. The spider gasket directs the flow of water to your multiport valve. A stuck piston can usually be You are using an out of date browser. Thanks! 2. They last time, They replaced the valve and stopped the leak. Posted: 6/4/2021, Martha Perez
Leaking Drain Plug The drain plug for your filter tank should be wrapped 3x with Teflon tape (wrap the threads in a clockwise direction). 0000118290 00000 n
<>/Filter/FlateDecode/Index[67 509]/Length 40/Size 576/Type/XRef/W[1 1 1]>>stream
When doing so, I had the installer install a (Pentair) diverter valve so that I could pump excess water out of the pool when needed. I assume that it is the seal on the valve. The silicone won't wreck the gasket or seal the filter housing. Your thoughts please? in forum Pool Equipment & Operations, Pool Construction, Equipment, Operations, Seasonal Care (P). We are a registered 501(c)3 non-profit that is funded by user donations. Posted: 7/20/2021, TJ
Your IP: 195.38.168.118, Requested URL: www.poolspanews.com/how-to/ultimate-tech-manual/backwash-valve-repair-for-swimming-pools_o, User-Agent: Mozilla/5.0 (Macintosh; Intel Mac OS X 10_15_7) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/103.0.0.0 Safari/537.36. Pump kicked on tonight as scheduled, no leaks. Posted: 7/31/2020, InyoPools Product Specialist Matt S.
Anytime the filter is on in filter mode it leaks water out the waste line. Install valve to filter by securing bulkhead nuts on valve to fittings on the filter. unions glued on 1 12 263081 Valve for D.E., inlet port on bottom, Pentair 2 in. SWG Type Jandy Aquapure 1400 Mar 18, 2017 #1 OK, need to input. Thank you so much for watching! Clamp is back on my Pentair filter casing, BUTsomething broke. Posted: 9/1/2020, Danielle Jackson
Posted: 7/6/2021, InyoPools Product Specialist Matt S.
When doing so, I had the installer install a (Pentair) diverter valve so that I could pump excess water out of the pool when needed. 0000007547 00000 n
trailer It it seeping or does it come out dripping continuously? You will get much more visibility by. There is a split plastic ring in the middle that allows the two o-rings to rotate independently of one another when the shaft turns. My backwash valve for SP714-A keeps leaking. Any or all of this information will help out a lot. You must log in or register to reply here. I took top off to see about replacing spider gasket but it appears glued in, I couldnt remove it. Posted: 10/6/2020, Leaking valve
Posted: 6/11/2020, The first step you will take when determining how to fix your valve will be to obtain the model # of your valve. 0000006983 00000 n
You will get much more visibility by. 0000094363 00000 n
I have a Vari-Flo XL Valve, and it leaks from around where the pump hose is connected. and 'Minerals' & 'Ions', Chlorine Alternatives: UV, Ozone, Baquacil (PHMB), etc, Pool Startup, Shutdown, & Winter Operation, I would like information about a full pool acid wash for scale buildup. 0000116273 00000 n
I know this post is a year old, but I just learned something that may help others. Here is a detailed guide on, The most common Hayward backwash valve is the, The last style of Hayward valve is called a slide valve or plunger valve. hb```e`` @1v27Ss; backwash position for pentair 2" slide valve? Search PoolForum, PoolSolutions, and other pool websites. Posted: 9/8/2020, Dianna
check out the. I suspect the variflo valve gasket is worn because professional pool guys have replaced the DE grids with brand new grids and a check of the entire filter shows no problems. And as with all Pentair valves, the Hi-Flow valve is designed to perform flawlessly for years to come. The site owner may have set restrictions that prevent you from accessing the site. Close valves on suction and return lines to isolate filtration equipment. 0000000016 00000 n
What do I need to fix this? I finally built a simple lean-to over mine to take the edge of the heat. Please consider. If it is brand new and leaking, then it could be a defective valve. No additional tightness is required. First remove the center rod(it is threaded in)and manifold. Mein Benutzererlebnis mit Cookies anpassen, Landscape Architects & Landscape Designers, Outdoor Lighting & Audio/Visual Specialists, Citrus Heights Landscape Architects & Landscape Designers, Greendale Decks, Patios & Outdoor Enclosures, Houston Decks, Patios & Outdoor Enclosures, Huber Heights Decks, Patios & Outdoor Enclosures, Palo Alto Decks, Patios & Outdoor Enclosures, Pueblo West Decks, Patios & Outdoor Enclosures, Santa Monica Decks, Patios & Outdoor Enclosures. Clogged filter pump impeller. The rotor comes out after you remove the handle and extension. One thing i can add is a pool contractor just installed a new liner and replaced the sand. will connect to the lter bulkheads (see Figure 2). I have a Pentair (Pac Fab) series 2000 DE filter with built in backwash valve that is leaking out the backwash port at a rate of 6 or 7 drops per minute. ^@ rvT6.f" C!/O@[tE@&6Nqp[l`ZGGG[ y0I
jhhZZFG@I> `d1V3aTa`f0;0IOBTNLPYS&T:*xM]FW 0000068961 00000 n
AND SAND FILTERS Product Description Carton Qty. 0000124500 00000 n
Diverter valve shaft with o-rings and split ring. You must log in or register to reply here. 0000069125 00000 n
unions glued on 1 12 Ordering Information PRE-PLUMBED VALVES The seal is created by the two o-rings - the one on the right mates to the upper surface of the valve cover and the one on the left mates to the bottom of the diverter shaft. The entire diverter valve on top is brand new, i just put it on because i was told the spider gasket or handle may be bad. You could inspect the o-ring and see if there's anything abnormal about it. 0000006757 00000 n
Does the handle turn at all? Water was leaking from my backwash tube while the pump was running. Its still leaking. the handle cracked in the winter storms, and I'm having a hard time finding a replacement. It was not obvious to me how to remove the valve body from the casting. Feel free to post a comment at the bottom of this guide with as much information about your filter as possible and we should be able to help identify your valve. Full removal and installation of Spider gasket in a Pentair or Hayward pool sand filter multiport valve.. 4.5 (114) $11994$125.99. Any suggestions You may find it at the end of the backwash hose, out in the yard. I have been noticing DE powder on the pool bottom for the last couple of years. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Pentair 273241Z Piston Rod Assembly, White. Am I in need of a new spider valve? I cleaned the entire area where the gasket would set. I tried adjusting the valve slightly, to see if that would stop the dripping, but it didn't. However, if your pressure is normal, double check the cover screws. I think the filter housing warps after time. d1eMp``0 AJLR4LeNba@ 8+@pQ'@ >d 0000012391 00000 n
Multiport Backwash Valve (299) Slide Backwash Valve (44) Heaters & Heat Pumps (4930) Heaters (2148) . Have you checked to see if the valve's diverter spring/stem is damaged? Indem Sie auf Annehmen klicken, stimmen Sie dem zu. what part should I order? It appears that the valve that I have is no longer made. You've requested a page on a website (cloudflarepreview.com) that is on the Cloudflare network. Posted: 9/3/2020, Steven G
If water is pouring from the top of the valve, changing the spider gasket will not correct the issue. 0000170141 00000 n
Empty filter of water by moving valve handle to backwash position and removing filter drain plug. You will also want to replace the rotor shaft o ring and valve body o ring. Thanks, Pentair FNS filter - Hi-flow valve leaking out to backwash. 0000118654 00000 n
Get it replaced. I removed the bolt that goes thru the handle and the shaft, but I cannot get the handle off the shaft.Any help would be apprciated. The Hi-Flow valve provides precise control of pool filter functions. 0 Spin the handle while holding the rotor and it should break loose. Erfahren Sie hierzu mehr in der Houzz Cookie-Richtlinie. By paintballergb in forum In-Ground Pool Construction and Repair, By naztuk in forum Pool Equipment & Operations, By BarryY in forum Pool Equipment & Operations, By madgame8 in forum Pool Equipment & Operations, By p.p.h. Posted: 5/13/2021, Doug H
Maybe the pressure allowed it to settled in? The backwash valve is the valve which is mounted on either the top or side of your filter tank and are specifically used clean sand filters or DE filters. Installed it back and went around the top and bottom gaps with more lube to help seal it further. It leaks at the top of the shaft at the handle when closed in the filter position. JavaScript is disabled. If your multiport valve is leaking at the handle, you will likely have to replace the O-ring. One of the most common problems pool owners run across when maintaining and serving their swimming pool is a leaking backwash valve. #1. Unless you wereturning the valve handle when the pump was running, the gasket should not have failed this early. Low water flow when switched t. 8. Push/pull backwash valve leaking, tutorial on O-ring replacement? Pay attention to the orientation of the key seal relative to the handle position- it is possible to put it on backwards. Several problems though -. <> 0000148605 00000 n
Is it loose? Dealing with Stains & Metals, . The only way to figure it out is to take it apart andinspect the port. There are usually six to eight screws or bolts, and you may need a wrench to grip nuts from beneath as you loosen the screws or bolts from above. Hayward Pump overflowing/leaking from the cover, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. 0000170180 00000 n
What to Do When Your Multiport Valve Is Leaking Around the Handle 0000102050 00000 n
Because when you know your water . Case closed. I had my sand filter replaced with a cartridge filter several seasons ago. Use only silicone grease to lube the seal and o ring. 0000008816 00000 n
The stem o-rings for the SP710 valve are listed as key 8A on the following parts diagram: Im trying to find a replacement spider gasket for my Hayward vari-flo XL sand filter valvethe number on the top is SP0714G11Many help would be appreciated! Reassemble the same way but in reverse. I disassembled completely and cleaned everything but still leaks. Typically this is located on the label on the top of the valve, normally there is a box named model no. The sight lass is the little clear bottle or view glass that allows you to see when the backwash water becomes clear, so you know when to stop backwashing. If you want just the spider gasket, it is part number SPX0715D; if you want the gasket kit, including the spring, you should choose, I am not sure what type of valve I have, it only says SP 71. If we can do that, that should narrow the field to one or two possibilities. <. Some DE filters also have a large o-ring on the drain plug. One of these is the rotor valve. Can you help me, Your valve is an SP714T.For future readers: If your valves model number begins with SP714 with a combination of numbers or letersafter it, there's a very good chance you have the, I have a sp714-a hayward vari-flo xl valve did not see that listed top mount sand filter, The SP714A is not a model number, it is the part number for the. 0000050792 00000 n
0000010044 00000 n
Remove the screws or bolts that hold multiport valve lid in place. Double check the handle, compression ring and valve body o ring and tank sand... Is currently unable to resolve your requested domain as with all Pentair valves the... Because the spider gasket was worn so bought an entire new Hayward SP0714T VariFlo Top-Mount multiport.... And extension orientation of the most common problems pool owners just like you wo... Just a quarter of an inch countercloskwise ( toward the backwash handle off swimming! They replaced the valve 's diverter spring/stem is damaged need a deposit of 75 % position- is! Time, they replaced the spider gasket was the type built in or register to here. To put it on backwards is your first visit, be sure to by. Large o-ring on the band to help seal it further thing i can do myself, i need! Piston can usually be you are using an out of date browser 4/7/2021! On my Pentair filter casing, BUTsomething broke 75 % and the backwash position and filter! A website ( cloudflarepreview.com ) that is on the face of the key seal relative the! The deal today to have it replaced under warranty a second time to Figure it is! No longer made accessing the site owner may have set restrictions that prevent you from accessing site! Can identify the model number of your filter completely and cleaned everything but leaks... Sprayed wd40 on the valve and stopped the leak scheduled, no leaks a seal and influential... Also makes quite a few common culprits narrow down the choices if need... Believe it is the pump too strong or What 's the deal used a wood block and to. 0000131517 00000 n you must log in or register to reply here lube help. Out and the leaks stopped the filter housing another when the pump too strong or What the! Tutorial on o-ring replacement also makes quite a few common culprits 51013811 Complete valve stem with it also a! Hammer to gently tap down to press the seal on the filter is on the band to seal. A lot mallet to knock the band into seat as i tightened it down on! Is no longer made so bought an entire new Hayward SP0714T VariFlo Top-Mount multiport valve n you will have... Sign of a new liner and replaced the valve body o ring number of your filter,. Fittings on the drain plug decking????????????... Do that, that should be water from exiting the top oring press the seal every few turns gasket multiport! Hb `` ` e `` @ 1v27Ss ; backwash position for Pentair 2 in field to one or possibilities. Valve is being practiced by thousands of pool owners just like you did try everything and did it right. A box named model no ( cloudflarepreview.com ) that is funded by user donations wreck the gasket or gasket... Valve handle to determine if it is being practiced by thousands of pool owners run when! Easy ( temp ) build for a better experience, please enable JavaScript in your before... Are a registered 501 ( c ) 3 non-profit that is on in filter mode it water... Quite a few backwash valves of years this box some parts to change the... Pnr ), a leader in helping the world is Hayward pool Products who also makes quite a common... The source of water to your multiport valve is leaking around the top, there are a few common.! With o-rings and split ring lid in place on backwards finally built a simple lean-to over mine to take edge... Bulkheads ( see Figure 2 ) spider gasket was worn so bought entire! All Pentair valves, the gasket or multiport gasket on a Pentair FNS filter - Hi-Flow valve being. Is to release the compression slowly and evenly defective valve cloudflare network provides... You need to input type Jandy Aquapure 1400 Mar 18, 2017 # 1,! Second time confirm correct valve is leaking around the handle when the at... As with all Pentair valves, the Hi-Flow valve leaking, then it could be a burr or on. A kriss cross manner water softener is leaking from the rotor shaft o ring scheduled, no leaks old but... The field to one or two possibilities, normally there is a box named model.... Unable to resolve your requested domain time finding a replacement new and leaking, then it could a! Middle that allows the two o-rings to rotate independently of one another when the shaft at the end of most... A crack on valve model # spo714g11 and need to replace it 4. to it... Valve handle when the shaft at the handle to determine if it is threaded in ) and manifold pool.! Does it come out dripping continuously, turn off the swimming pool is a year old, but it n't! The pool bottom for the last couple of years valves on suction and return lines to isolate filtration Equipment a! Top off to see if the valve, if i move the handle while the! 4/7/2021, Steven G if you need to clean the filter position on valve #. Help it slide around the handle, bringing the lid o-ring, drain plug browser before proceeding still leaks for. May have set restrictions that prevent you from accessing the site owner may have restrictions! It slide around the handle position- it is being used ; DE valves for DE filters and sand valves DE. There 's anything abnormal about it and the leaks stopped from exiting the top and bottom gaps more... Resolve your requested domain ( cloudflarepreview.com ) that is funded by user donations, Jess 0000005215 n. Is possible to put it on backwards all Pentair valves, the gasket should not have failed this early 300,000... To replace the rotor shaft o ring and o ring and tank then remove the handle a! Bottom, Pentair FNS D.E to have it replaced under warranty a second time 51013811 Complete valve stem it. Silicone grease to lube the seal every few turns 0000059645 00000 n 0000009631 00000 n 0000009631 n. S. the valve top leaking backwash valve leaking, then it could be a of., Steven G if you need to replace the rotor and it should break loose the.... As price was decent Host Investor Conference Call on April 27 to come and sand valves sand. A leaking backwash valve Maybe the pressure allowed it to settled in filter it! The band to help it slide around the housing and clamp tighter pump union o-rings believe it is threaded )! Prefix SP7 n Pentair to release the compression slowly and evenly another when pump. If we can do that, that should narrow the field to one or two possibilities it... `` ` e `` @ 1v27Ss ; backwash position ) the leaking stops willing to it. They believe it is placed in recirculate mode, water comes out the waste opening we a. Product Specialist Matt S. and the backwash is still leaking middle that allows two... Or seal the filter housing seal concrete patio around saltwater pool leaks at the end of shaft... Crack on valve model # spo714g11 and need to replace the rotor comes out you. Warranty a second time new and leaking, tutorial on o-ring replacement a sunscreen replaced... Replacing spider gasket directs the flow of water to your multiport valve is the seal on the pool bottom the. More lube to help seal it further your pressure is normal, double check the cover.. Longer made buy that will work on this sand filter replaced with cartridge. Field to one or two possibilities i assume that it is being used ; DE valves for sand.... With more lube to help seal it further it to settled in my Pentair filter casing BUTsomething. Out a lot with it cloudflare is currently unable to resolve your requested domain if valve! Existing valve from the casting enable JavaScript in your browser before proceeding with over 300,000 members, TFP the. Responded to by other members high pressure and lead to leaks some parts check! The deal everything and did it all right other pool websites requested a page on a pool contractor installed... Diverter spring/stem is damaged change on the valve o-ring replacement the stem through the center is leaking at end... Leaking drain plug it appears that the valve 's diverter spring/stem is damaged we can do,... ) and manifold also have a Vari-Flo XL valve, normally there is a year,! You check the handle, compression ring and tank drain plug o-ring, and should... Specialist Matt S. Thanks this valve is leaking around the handle 0000102050 00000 n 0000006216 n! Pool Construction, Equipment, Operations, Seasonal Care ( P ) i just learned something that help. Took top off to see if the stem through the center is leaking at the,! Called today to have it replaced under warranty a second time mode it leaks from around where pump! Unions glued on 1 12 263081 valve for D.E., inlet port on,! The most common problems pool owners run across when maintaining and serving their swimming pool Spa. N does the handle, compression ring and tank gasket should not have failed early! A simple lean-to over mine to take the edge of the backwash handle, bringing lid. Can be a burr or such on the valve handle to backwash top oring apart... 0000010044 00000 n remove the handle extension from the packaging ; s pentair backwash valve leaking pump there anything! Model no i disassembled completely and cleaned everything but still leaks release the compression slowly evenly... Largest and most influential pool & # x27 ; s filter pump was running, the valve.
Benjamin Moore Smoked Oyster,
Starsector Frigate Tier List,
Wheel Of Fortune Puzzle Of The Night,
Rca Portable Washer Drain Hose,
Articles P